Single Phase Two Winding Ideal Transformer
Description of the Single Phase Two Winding Ideal Transformer component in Schematic Editor.
Component description
Note: In software release versions 2025.3 and earlier, this component was named
Ideal Transformer
The single-phase two winding ideal transformer is composed of an ideal current controlled current source on one side and an ideal voltage controlled voltage source on other side. The number of turns on current source side and the number of turns on voltage source side can be set through parameters N1 and N2. The transfer ration of the ideal transformer can be calculated as:
Ports
- prm_1 (electrical)
- Primary (current source side) winding port 1.
- prm_2 (electrical)
- Primary (current source side) winding port 2.
- sec_1 (electrical)
- Secondary (voltage source side) winding port 1.
- sec_2 (electrical)
- Secondary (voltage source side) winding port 2.
Parameters
- n1
- Number of turns on primary (current source) side.
- n2
- Number of turns on secondary (voltage source) side.