User Power Supply
Power limits for HIL606 devices
In order to simplify the design of the interface board between the HIL and the controller under test, the HIL system provides analog and digital power to the interface board. In many cases, this power may be sufficient to also supply the controller under test, thus significantly simplifying the HIL test setup.
Warning: The User PSU section is not designed to
sink current, and will be damaged if an external voltage source is applied to
the output.
HIL606 power limits
Voltage Level | Current limit | Comment |
---|---|---|
+12Va | 2 A | Resettable protection, filtered |
-12Va | 2 A | Resettable protection, filtered |
+5Va | 2 A | Resettable protection, filtered |
-5Va | 2 A | Resettable protection, filtered |
3.3Vd | 2 A | Resettable protection, filtered |
5Vd | 2 A | Resettable protection, filtered |